This is the topmost object in the hierarchy, and there will be only one of these objects for a simulation. It contains settings controlling details of the calculation, such as the units used. The data files PGOPHER uses (.pgo) thus contain one mixture, with all other objects contained within it, and the name of the mixture will normally be the name of the file. The Mixture object contains one or more Species and Simulation objects and an optional Correlations object.
Note that many or the parameters were moved into the Simulation object in version 5.2.
Units | Units for calculation of frequencies/energy - valid
values are cm1 (cm-1), MHz, Kelvin and eV. The key change
this makes is in
calculating Boltzmann factors from temperature and for selected
intensity units; the units are otherwise
not significant. |
PrintLevel | Controls the
amount of printout in the Log window.
Possible values, in order of increasing amount of output are:
|
Precision | Precision of printout (decimal places after the point). |
BasisOrder | How to order the basis states making up a basis. Valid values are: boDefault, boDiagonal and boStateDiagonal. |
QuantumNumberFormat | Controls how quantum numbers are read and displayed.Possible
values are:
|
FitCycles | Number of least squares fit cycles to do on each press of a "fit" button. |
FitDetails |
If true, display more
information following a fit, currently a singular value decomposition
of the parameters. |
AutoReplot | If false, automatic recalculation of the simulation is disabled in some circumstances. Use if the program is running slowly. |
AllowComplex | If set, calculations will be
performed using complex wavefunctions if there are matrix elements that
require it. Otherwise purely imaginary matrix elements are forced to be
real. |
NoLineList | Disable the use of recorded line
lists during simulations. This disables some features, such as the
ability to right click on a line to identify it, but allows larger
calculations to be performed. For example, the maximum J in a simple asymmetric top
calculation is increased from about 200 to 500 with this setting. |
ShowEstUnc |
Show estimated uncertainties of
line positions in the line
list window and in line lists (use PrintLevel
= LineList or Export a
line list from the File menu). |
ShowDerivatives | Show derivatives with respect to
parameters in line lists. |