| <Prev Next> | 
This window displays the position, assignment and intensity of lines in the simulated spectrum. It appears when right-clicking on a peak in a simulated spectrum, and on each click all the lines close to the clicked position are added to this window, with the most intense first. You can adjust the number of lines added from the Line List Options Window. Simple line position fits can also be done directly from this window, though for anything other than the simplest of fits more the line lists are best placed in a text file as only limited editing is possible in the this window. (An initial text file can be created by copying and pasting from the line list window.) The contents of this window are normally (for version 5.2 and above) saved to and loaded from the .pgo file.
Click on an item in the picture below for more information:
    ![]()  | 
          Set
            frequency of selected lines
            from clipboard, assuming a number is available as text on
            the
            clipboard. The standard deviation is also set to 1.
            Measuring a peak by
            right
            clicking and dragging
            over a peak in an experimental or simulated spectrum in PGOPHER puts the
            peak position
            on the clipboard for this purpose. If the neighboring "Auto"
            item is
            checked (the default) this assignment is done automatically
            each time a
            peak in an experimental spectrum is measured. A blue line in
            the
            experimental spectrum will appear, indicating the measured
            peak
            position. | 
        
![]()  | 
          If on, assign measured peak to selected transitions automatically (if off, this can be done manually using Assign). | 
![]()  | 
          Show difference between first and last line selected. | 
![]()  | 
          Select all lines in the line list window. | 
![]()  | 
          Select no lines. | 
![]()  | 
          Copy
            selected lines to clipboard
            and delete them. | 
        
![]()  | 
          Copy selected lines to clipboard. | 
![]()  | 
          Delete selected lines. | 
![]()  | 
          Delete all lines. | 
![]()  | 
          Delete unassigned lines, i.e.
            those with the standard deviation column empty. | 
        
![]()  | 
          Menu for more actions:
  | 
        
![]()  | 
          Plot assignments and display residuals | 
![]()  | 
          Fit observations in this window | 
![]()  | 
          Reset parameters to the value
            before the last fit cycle. This button is disabled until a
            fit has been
            done. | 
        
| Molecule | The molecule responsible for this transition. | 
| M' | Manifold for the upper state of the transition | 
| J' | Upper state total angular momentum or M'. (M' in the presence of
            static field,
            otherwise J' in
            the absence
            of hyperfine
            structure, otherwise F'). | 
        
| S' | Symmetry of the upper state. | 
        
| #' | Eigenvalue number for upper state. This gives the index (starting from 1) of the upper energy level with respect to other levels of the same total angular momentum and symmetry. | 
| M'' | Manifold for the lower state of the transition | 
| J'' | Lower state total angular momentum or M". (M" in the presence of static field, otherwise J' in the absence of hyperfine structure, otherwise F'). | 
| S'' | Symmetry of the lower state. | 
| #'' | Eigenvalue number for lower state. This gives the index (starting from 1) of the upper energy level with respect to other levels of the same total angular momentum and symmetry. | 
| Position | The position of the transition; the units for this are the
            units used in the main simulation window. For line position
            fitting,
            alter this number to the position of the observed peak,
            either manually
            or (more usually) with the assignment process described
            under line
              position fits. | 
        
| Std Dev | 
          The (relative) standard deviation of this transition, used to calculate the weight of the observation in a line position fit. If this is negative, zero or blank this transition will not be included in the fit. Entries will initially have this blank or negative, and the automatic assignment process will set this to 1. Less certain measurements can be given larger values. Note that the parameters produced by a fit only depend on the relative values of the weights. If ShowEstUnc is set at the top level, then this column is set to the negative of the estimated uncertainty of the transition, based on the errors in the most recent fit, if available. | 
| Strength | The intensity of the rotational transition. | 
| Width | The width of the transition. (Note that this does not
            include
            the Gaussian or Lorentzian width set on the plot window.) | 
        
| deltaJ(J'') | The transition label in branch notation, such as P(1). The
            display will depend on the molecule type and the electronic
            and nuclear
            angular momenta included in the calculation. | 
        
| Name | Details of the transition, including other quantum numbers
            where appropriate. The assignment process will also add the
            source of
            the measurement (typically a filename) where possible. |