Objects Overlays | <Prev Next> |
Units | Horizontal Axis units. |
IntensityUnits | Selects vertical units for plot. This has the same
possible values as for a simulation,
though the interpretation is slightly different:
|
Colour | Colour for plot. |
Hide | Hide this plot |
ZeroValid | Set if zero in data is correct. |
AutoMin | If set, Ymin automatically updated to minimum point in plot range |
AutoMax | If set, Ymax automatically updated to maximum point in plot range |
FixCentre | Select style of frequency scaling; see FrequencyScale below. |
FirstPoint | First point to use in fitting and plotting. (Note that the point number under the mouse is shown at the bottom of the overlays window). |
LastPoint | Last point to use in fitting and plotting. |
IsLineList | Set to treat data as a list of line positions, optionally with intensity. |
Convolute | Set to convolute experimental spectrum with simulation linewidth(s). |
ComponentType | (Future Use) |
FrequencyOffset | Frequency offset used when displaying plot. Note this is distinct from Offset in the constants window (and in the main window), which changes the frequency offset of the simulation. |
FrequencyScale | Scaling factor for horizontal scale. The correction
formula used is: If FixCentre is
clear (default):
f' = (f-fav)*FrequencyScale
+
FrequencyOffset
where fav is the
average of the highest and lowest frequencies. This means
that the centre of the plot only shifts by
FrequencyOffset, regardless of the scale used.
Note that FixCentre
was introduced in version 5.2.861; earlier versions assumed
FixCentre set, so older overlay files will need adjustment.
If FixCentre is set: f' = f*FrequencyScale
+
FrequencyOffset
|
Ymin | Lower end of current plot range; overwritten with lowest value in current range if AutoMin set |
Ymax | Upper end of current plot range; overwritten with lowest value in current range if AutoMin set |
Baseline | Baseline position. |
Scale | Vertical scale factor used in plotting. |